Sidearm Heat Exchangers

    Designed using the natural thermo-siphon on the domestic hot water side, our sidearm heat exchangers not only provide faster heating at a greater capacity than traditional sidearms, they prevent cross contamination in potable water application.

    While the capacity of traditional sidearm heat exchanger is determined by the length of sidearm tubes and their heat transfer efficiency is comparitively very low. Instead of using two bare copper tubes,our fin-enhanced heat exchangers made of stainless steel and will have high heat transfer efficiency resulting from the utilization of an internal finned tube. This fin-enhanced design has a surface are five to eight times bigger than the bare tube design and produces significant turbulence on the system side. Our fin-enhanced sidearms provide a larger capacity and faster hearing using a shorter unit. Fin-enhanced sidearms are available upon request. Download the Sidearm Heat Exchanger Brochure.

    Double Wall Sidearm Heat Exchangers
    Concerns about cross contamination of potable water has forced several US States to enact several regulations designed to prevent this from happening. Double wall sidearm heat exchangers present the most effective means of protection from cross contamination. Our vented double walled sidearm meets all the criteria of these regulation.

    Applications of the Sidearm Heat Exchanger
    Due to its compact size and lightweight, these sidearm heat exchangers come highly recommended for use in domestic water heating and residential plumbing applications. Also called domestic water heat exchangers, they are typically used to heat domestic water using either a conventional boiler, outdoor wood furnace or a solar hot water system.


    1. Domestic Hot Water Heating
    2. Outdoor Wood Furnances
    3. Solar Hot Water Heating
    Typically the domestic water is circulated by means of the thermosiphon principle which saves on the cost of a pump and the associated electrical costs. In cases where faster heat recovery is required the domestic hot water should be circulated by means of a pump. Pump circulation will typically provide a heat recovery 3 to 4 times greater than thermo-siphoning. We offer the following three models:

    Model No.

    BTU/hr

    Length

    Connection size

    Construction

    C-C Distance

     

     

     

    DHW Side

    System side

     

    System Side

    FES-115

    22500

    975mm

    3/4"NPT

    3/4"NPT

    SS304

    855mm

    FES-115DW

    18000

    975mm

    3/4"NPT

    3/4"NPT

    SS304

    855mm

    FES-95

    18500

    840mm

    3/4"NPT

    3/4"NPT

    SS304

    720mm


    Download Brochure